169 research outputs found

    METROLOGICAL SUPPORT OF DOSIMETRY GAMMA-RAY WITH ENERGY TO 10 MEV FOR RADIATION PROTECTION DEVICES

    Get PDF
    The field of high-energy gamma-ray for the calibration of radiation protection devices can be obtained by capturing thermal neutrons from titanium target (to 7 MeV) and nickel target (to 10 MeV). The aim of this work was to determine the metrological characteristics of capture gamma-ray fields from titanium target and nickel target obtained at the AT140 Neutron Calibration Facility to provide dosimetry up to 10 MeV.We have chosen energy intervals in which we can calibrate dosimetry devices taking into account the accompanying generation of gamma-ray neutrons by the fast neutron source 238PuBe, the capture radiation of collimator materials and capture radiation from targets.We measured air kerma rate with the aid of the reference AT5350 dosimeter with the ionization chamber TM32002. Using the Monte-Carlo simulation, we obtained the energy distribution of the air kerma rate for targets. We determined the geometric dimensions of the uniform field and the interval of operating distances of the facility.We investigated the metrological characteristics of capture gamma-ray fields from titanium target and nickel target obtained at the AT140 Neutron Calibration Facility for dosimetric radiation protection devices. We showed that in such fields it is possible to calibrate dosimetry devices in the extended energy range up to 10 MeV

    Determinant Structure of the Rational Solutions for the Painlev\'e IV Equation

    Full text link
    Rational solutions for the Painlev\'e IV equation are investigated by Hirota bilinear formalism. It is shown that the solutions in one hierarchy are expressed by 3-reduced Schur functions, and those in another two hierarchies by Casorati determinant of the Hermite polynomials, or by special case of the Schur polynomials.Comment: 19 pages, Latex, using theorem.st

    ценка двигательной адаптации здоровых лиц по данным пространственно-временной кинематики

    Get PDF
    An important problem of modern clinical biomechanics is to identify complex movement markers that make it possible to evaluate complex motor adaptive reactions regardless of age, gender, and anthropometric deviations. The purpose of the present study was to develop a method for analysis of human motor adaptive reactions based on calculating specific biomechanical markers obtained by performing diverse kinematic tests. The study involved 90 volunteers with a right-leading kinematic side at an age of 18.8 [16.8/20.8] years, with a height of 171.8 [179.2/164.8] cm, a body weight of 65.3 [76.6/58.5] kg, and the ratio of men and women – 5 : 4. During the study, all participants underwent biomechanical analysis using the TESLASUIT remote motion capture suit and performing diverse kinematic tests. In the course of the study, a new method for analyzing human motor adaptive reactions was developed. It is based on calculating specific time markers of the active phase, average angular deviation markers, and inertial kinematic markers. All markers are calculated after each kinematic tests “frontal stability”, “sagittal stability”, “spatial orientation”, and “stimulus identification”. Our survey revealed that specific (p < 0.001) markers of the first test are the time indicators of the active phase, the markers of the second and fourth tests are associated with the average angular deviation parameters, and the specific indicators of the third test can be the inertial kinematics of thighs, legs, and feet.Актуальной проблемой современной клинической биомеханики остается выделение маркеров сложных движений, позволяющих оценивать сложные двигательные приспособительные реакции вне зависимости от возраста, пола и антропометрических девиаций. Цель исследования: разработать метод анализа двигательных приспособительных реакций человека по биомеханическим маркерам, полученным при выполнении разноплановых кинематических тестов. В исследовании приняли участие 90 добровольцев с правосторонним ведущим кинематическим звеном в возрасте 18,8 [16,8/20,8] лет, с ростом 171,8 [179,2/164,8] см и массой тела 65,3 [76,6/58,5] кг, соотношение мужчин и женщин – 5 : 4. В ходе исследования всем участникам проводили биомеханический анализ с применением системы дистанционного захвата движений «TESLASUIT», а также выполняли разноплановые кинематические тесты. В ходе проведения исследования разработан новый метод анализа двигательных приспособительных реакций человека, основанный на вычислении специфических маркеров времени активной фазы средней угловой девиации и инерциальной кинематики при выполнении стандартизированных кинематических тестов «фронтальная стабильность», «сагиттальная стабильность», «пространственная ориентация» и «идентификация стимула». Установлено, что специфическими (р < 0,001) маркерами первого теста являются показатели времени активной фазы, маркеры второго и четвертого тестов связаны с параметрами средней угловой девиации, специфическими индикаторами третьего теста может выступать инерциальная кинематика бедер, голеней и стоп

    Влияние полноты реализации программы ускоренного выздоровления пациентов, перенесших резекцию ободочной кишки по поводу рака, на эффективность лечения

    Get PDF
    Objective: to assess ERP implementation results in patients with colon cancer and to reveal correlation between compliance of ERP protocol and efficacy of perioperative care.Materials and methods. 124 patients were included in the study. Main group consisted of 62 patients with ERP, others were controls. ERP compliance was assessed using original formula which considers number of accomplished elements of the Protocol and quality of performance of each element.Results. No significant difference between the groups in morbidity was obtained (1.6 % in main group vs 9.8 % controls; р = 0.06). Minor dependence in self-care was obtained in 90.5 % at third post-op day in main group vs 58.0 % in controls (p < 0.0001). Postoperative hospital stay was lower in main group (4.7 ± 0.1 vs 9.0 ± 0.6 days; p < 0.0001). Total hospital stay was lower in main group as well (7.2 ± 0.1 vs 14.1 ± 0.7 days; р < 0.0001). No mortality and readmissions occurred. ERP compliance rate was 80.0 % (56.9–93.3 %). Рostoperative hospital stay in patients with high protocol compliance (≥ 80 %) was significantly shorter then in patients with low protocol compliance (< 80 %): 4.3 ± 0.2 vs 5.1 ± 0.2; р = 0,005).Conclusion. ERP is effective and safe method of postoperative care in patients after colon resection and the effectiveness of the treatment correlates with protocol compliance rate resulted in shorter hospital stay.Целью работы стала оценка непосредственных результатов применения программы ускоренного выздоровления (ПУВ) пациентов, подвергшихся операциям на ободочной кишке, и изучение влияния полноты ее реализации на эффективность лечения.Материалы и методы. В исследование включены 124 пациента. Первую (основную) группу составили 63 больных, в отношении которых которых была применена ПУВ. Пациенты 2-й (контрольной) группы (n = 61) получали стандартное лечение. Для подсчета процента реализации ПУВ нами разработана формула, учитывающая не только количественную реализацию элементов программы, но и качество выполнения каждого из заявленных элементов.Результаты. Частота послеоперационных осложнений в группах и подгруппах достоверно не отличалась (1,6 % (n = 1) – в основной и 9,8 % (n = 6) – в контрольной; р = 0,056). Количество послеоперационных койко-дней ниже в основной группе и составила 4,7 ± 0,1 по сравнению с 9,0 ± 0,6 в контрольной (р < 0,0001). Достоверно ниже было и число общих койко-дней в основной группе (7,2 ± 0,1 против 14,1 ± 0,7 в контрольной (р < 0,0001)). Случаев повторной госпитализации и летальности не отмечено. Доля реализации ПУВ в нашей клинике составила от 56,9 до 93,3 %, медиана – 80 %. Число послеоперационных дней у пациентов с реализацией программы на 80 % и более был достоверно ниже, чем у пациентов с реализацией ПУВ < 80 %: 4,3 ± 0,2 против 5,1 ± 0,2, (р < 0,0001).Заключение. Предложенная ПУВ является эффективным и безопасным методом ведения пациентов, подлежащих хирургическому лечению по поводу рака ободочной кишки. Эффективность лечения, ассоциированная с укорочением сроков пребывания в стационаре, коррелирует с процентом реализации ПУВ

    Rational Solutions of the Painleve' VI Equation

    Full text link
    In this paper, we classify all values of the parameters α\alpha, β\beta, γ\gamma and δ\delta of the Painlev\'e VI equation such that there are rational solutions. We give a formula for them up to the birational canonical transformations and the symmetries of the Painlev\'e VI equation.Comment: 13 pages, 1 Postscript figure Typos fixe

    Internal scheme of the body assessment in an experiment with environmental uncertainty

    Get PDF
    The aim of the work was to analyze the influence of various environmental factors forming environmental uncertainty on the nature of the transformation of the "internal scheme of the body". Materials and methods. For the study, a group of healthy volunteers (n = 90) was selected. The results in this paper are median, 75 and 25 percentiles (Me [UQ / LQ]). The study was conducted in several stages. At the first stage, the criteria for excluding potential participants from the experiment were formed. At the second stage of the study, a video analysis of the main anatomical orientations of the pelvic region in static and dynamic samples was conducted for all participants. Conclusion. In the course of the study, specific patterns of spatial deviations of biomechanical blocks of the pelvic region were established, triggered by changes in the qualitative and quantitative parameters of the external environment. So, in conditions of static equilibrium, coordination is activated with involvement of the anterior and posterior half-rings of the pelvis (frontal biomechanical blocks); in conditions of dynamic equilibrium, diagonal biomechanical blocks of the pelvic region are activated; in conditions of deprivation of visual afferentation, the compensatory reactions of the lateral semirings of the pelvic region (lateral biomechanical blocks) are formed

    ВЛИЯНИЕ РЕКОМБИНАНТНОГО ЛАКТОФЕРРИНА ЧЕЛОВЕКА НА УРОВЕНЬ ПОЛОВЫХ ГОРМОНОВ У САМЦОВ КРЫС РАЗНОГО ВОЗРАСТА

    Get PDF
    A systemic administration of human recombinant lactoferrin to male rats caused an increase in a total testosterone level by 200 % in blood serum, the estradiol concentration decreased significantly by 16.7 %. Upon completion of administration, testosterone was still increased (p < 0.05) for 7 weeks, gradually returning to the control group values without inhibition of endogenous testosterone synthesis. In contrast, the level of estradiol returned to control values. Our study of the rat model of age-related hypogonadism revealed that a systemic per os administration of human recombinant lactoferrin to experimental animals had a significant stimulatory effect on testosterone biosynthesis in 2-yearolds, restoring it to the level of physiological values in young rats. Системное введение рекомбинантного лактоферрина человека молодым (2 мес.) крысам-самцам вызывало увеличение уровня общего тестостерона в сыворотке крови на 200%. После завершения курсового введения содержание тестостерона оставалось повышенным (р < 0,05) в течение семи недель, постепенно возвращаясь до значений контрольной группы без угнетения биосинтеза эндогенного тестостерона. В модели возрастного гипогонадизма системное влияние per os рекомбинантного лактоферрина человека экспериментальным животным оказывало значительное стимулирующее действие на биосинтез тестостерона у 2-летних особей, нормализируя его уровень до физиологических значений молодых крыс.

    The Hamiltonian Structure of the Second Painleve Hierarchy

    Full text link
    In this paper we study the Hamiltonian structure of the second Painleve hierarchy, an infinite sequence of nonlinear ordinary differential equations containing PII as its simplest equation. The n-th element of the hierarchy is a non linear ODE of order 2n in the independent variable zz depending on n parameters denoted by t1,...,tn1{t}_1,...,{t}_{n-1} and αn\alpha_n. We introduce new canonical coordinates and obtain Hamiltonians for the zz and t1,...,tn1t_1,...,t_{n-1} evolutions. We give explicit formulae for these Hamiltonians showing that they are polynomials in our canonical coordinates

    ИСТОЧНИК ЗАХВАТНОГО ГАММА-ИЗЛУЧЕНИЯ С ЭНЕРГИЯМИ ДО 7 МэВ И ДО 10 МэВ НА ОСНОВЕ ПОВЕРОЧНОЙ УСТАНОВКИ НЕЙТРОННОГО ИЗЛУЧЕНИЯ

    Get PDF
    Wide spread of technogenic sources of ionizing radiation such as particle accelerators and nuclear reactors leads to appearance of a number of applied metrological tasks aimed at providing spectrometric and dosimetric ionization measurement instruments, located in photon radiation fields with energy to 10 MeV. Gamma rays with energy higher 3 MeV may be acquired using radioactive thermal neutron capture on target, i.e. (n, γ)-nuclear reaction. Titanium is used in the range of energies to 7 MeV; nickel – to 10 MeV. A simplest source of instantaneous neutron capture gamma-ray should consist of fast neutron source, neutron moderator and a target irradiated with thermal neutrons. The collimator with thermal neutron geometry of АТ140 neutron calibration facility with 238Pu–Be fast neutron source may be used (IBN–8–6) as a source of gamma-ray with energy to 10 MeV. Monte-Carlo models of thermal neutrons geometry, facility and 238Pu–Be fast neutron source were built using MCNP–4b code. Energy distribution of flux density of neutron capture gamma–ray for titanium and nickel targets was defined. A spectrometric detector based on LaBr3(Ce) crystal Ø 38×38 mm with non-linear characteristics of channel-energy transformation in the range up to 10 MeV, was specifically manufactured for instrumental support of the experiment at SPE “ATOMTEX”. The results for Ti, Ni, and for bare 238Pu–Be neutron source were acquired. During the experiment a possibility to use neutron capture gamma-ray field formed by thermal neutrons geometry of АТ140 neutron calibration facility with 238Pu–Be-fast neutron source with Ti and Ni targets for calibration LaBr3(Ce) spectrometers for energy to 10 MeV was confirmed. Closely stationing polyethylene plate in collimator channel provides significant increase in output of reference radiation from target simultaneously decreasing unneeded parts of the spectrum. Широкое распространение и использование техногенных источников ионизирующих излучений, в частности таких, как ускорители заряженных частиц и ядерные реакторы, приводит к появлению ряда прикладных задач по метрологическому обеспечению спектрометрической и дозиметрической аппаратуры, работающей в полях фотонного излучения с энергией до 10 МэВ. Контейнер-коллиматор с геометрией тепловых нейтронов установки поверочной нейтронного излучения (УПН- АТ140, УП «АТОМТЕХ») формирует коллимированный пучок нейтронов со значительной составляющей нейтронов тепловых энергий. Расположение в потоке тепловых нейтронов диска из титана позволяет получить поле захватного гамма-излучения до 7 МэВ, а диска из никеля – до 10 МэВ. Для экспериментального изучения спектральных характеристик поля захватного излучения использовался специализированный спектрометрический блок детектирования на основе кристалла LaBr3(Ce) с размерами Ø 38×38 мм с нелинейной характеристикой преобразования канал-энергия в диапазоне до 10 МэВ. На спектрах хорошо различимы основные линии захватного излучения от водорода, бора, титана и никеля. По полученным на блоке детектирования спектрам можно сделать вывод о возможности калибровки спектрометрических блоков в поле захватного гамма-излучения до 10 МэВ.
    corecore